• C203 provides basic but robust control functionality for any Inxpect safety radar sensor. The Inxpect Safety Application works via USB to configure the sensitivity levels, safety functions, size of detection fields, and the functionality of the I/O ports of the control unit.
    USB: Local configuration option.
    Digital inputs: The system has two TYPE3 dual channel inputs. Alternatively, the four channels can be used as single channel digital inputs (category 2). Supporting the following functions:
    • Muting signal
    • Emergency stop signal
    • Restart signal
    Four Signal Switching Devices
    • As safety outputs: two dual-channel safety OSSDs.
    • As auxiliary outputs: four auxiliary outputs, which can be configured as signal restart feedback, fault, muting status.
    Dynamic setting of detection fields: There are up to 8 configurations switchable in real time. SD backup, SD restore: Configurations and login credentials can be saved and restored via microSD card (only for C203B) Type B:
    • C203B (Core Line) Part No. 90304111
    • C203B-X1 (eXtended Line) Part No. 90304111.2B0
  • C201 is the most advanced control unit for Inxpect safety radars, with the widest range of communication options. The Inxpect Safety Application allows the configuration of sensitive levels, safety functions, size detection fields, and the functionality of the I/O ports of the control unit.
    Safety fieldbus: Currently supporting Safety over EtharCAT® (FSoE) fieldbus protocol.
    Secure Ethernet: Remote configuration and management protected by industry standard cyber security protocols.
    USB: Local configuration option.
    Digital inputs: The system has two TYPE3 dual channel inputs. Alternatively, the four channels can be used as single channel digital inputs (category 2). Supporting the following functions:
    • Muting signal
    • Emergency stop signal
    • restart signal
    Four Output Sinal Switching Devices:
    • As safety outputs: two dual-channel safety OSSDs
    • As auxiliary output: four auxiliary outputs, which can be configured as signal restart feedback, fault, muting status.
    Dynamic setting of detection fields: The FSoE connection allows to have up to 32 configurations switchable in real time. Type A:
    • C201A-F (Core line) Part no. 90301012
    • C201A-FX1 (eXtended line) Part no. 90301012.2BO
    The eXtended Line supports new advanced functions. It also supports S202A sensors and Inxpect Safety Studio application.
  • C201A is the most advanced control unit for Inxpect safety radars, with the widest range of communication options. The Inxpect Safety Application allows the configuration of sensitivity levels, safety functions, size of detection fields, and the functionality of the I/O ports of the control unit. Safety fields: Currently supporting PROFIsafe fieldbus protocol. Secure Ethernet: Remote configuration and management protected by industry standard cyber security protocols. USB: local configuration option. Digital inputs: The system has two TYPE3 dual channel inputs. Alternatively, the four channels can be used as single channel digital inputs (category 2). Supporting the following functions:
    • Muting signal
    • Emergency stop signal
    • Restart signal
    Four output signal switching devices:
    • As safety outputs: two dual-channel safety OSSDs
    • As auxiliary output: four auxiliary outputs, which can be configured as signal restart feedback, fault, multi status.
    Dynamic setting of detection fields: The PROFIsafe connection allows to have up to 32 configurations switchable in real time. Type A:
    • C201A-PNS (core line) Part no. 90301011
    • C201A-PX1 (eXtended line) Part no. 90301011.2B0 (The eXtended Line supports new advanced functions. It also supports S202A sensors and Inxpect Safety Studio application.)
  • C201 is the most advanced control unit for Inxpect safety radars, with the widest range of communication options. The Inxpect Safety Application allows the configuration of sensitivity levels, safety functions, size of detection fields, and the functionality of the I/O ports of the control unit.
    Safety fieldbus: Currently supporting Safety over EtherCAT® (FSoE) fieldbus protocol.
    Secure Ethernet: Remote configuration and management protected by industry standard cyber security protocols.
    USB: Local configuration option.
    Digital inputs: The system has two TYPE3 dual channel inputs. Alternatively, the four channels can be used as single channel digital inputs (category 2). Supporting the following functions:
    • Muting signal
    • Emergency stop signal
    • Restart signal
    Four Output Signal Switching Devices:
    • As safety outputs: Two dual-channel safety OSSDs.
    • As auxiliary outputs: Four auxiliary outputs, which can be configured as signal restart feedback, fault, muting status.
    Dynamic setting of detection fields: The FSoE connection allows to have up to 32 configurations switchable in real time. SD backup, SD restore: Configurations and login credentials can be saved and restored via microSD card (only for C201B). Type B:
    • C201B-F (Core Line) Part no. 90301112
    • C201B-FX1 (eXtended Line) Part no. 90301112.2BO
    The eXtended Line supports new advanced functions. It also supports S201A sensors and Inxpect Safety Studio application.
  • C201A is the most advanced control unit for Inxpect safety radars, with the widest range of communication options. The Inxpect Safety Application allows the configuration of sensitivity levels, safety functions, size of detection fields, and the functionality of the I/O ports of the control unit. Safety fieldbus: Currently supporting PROFIsafe fieldbus protocol. Secure Ethernet: Remote configuration and management protected by industry standard cyber security protocols. USB: Local configuration option. Digital inputs: The system has two TYPE3 dual channel inputs. Alternatively, the four channels can be used as single channel digital inputs (category 2). Supporting the following functions:
    • Muting signal
    • Emergency stop signal
    • Restart signal
    Four Output Signal Switching Devices:
    • As safety outputs: two dual-channel safety OSSDs.
    • As safety outputs: four auxiliary outputs, which can be configured as signal restart feedback, fault, muting status.
    Dynamic setting of detection fields: The PROFIsafe connection allows to have up to 32 configurations switchable in real time. SD backup, SD restore: Configurations and login credentials can be saved and restored via microSD card (only for C201B). Type B:
    • C201B-P (Core line) Part no. 90301111
    • C201B-PX1 (eXtended line) Part no. 90301111.2BO
    The eXtended Line supports new advanced functions. It also supports S202A sensors and Inxpect Safety Studio application.  
  • C201B-C provides a safety communication based on CIP Safety™ on EtherNet/IP™. The Inxpect Safety Application allows the configuration of sensitivity levels, safety functions, size of detection fields, and the functionality of the I/O ports of the control unit. Safety fieldbus: CIP Safety™ over EtherNet/IP™. Secure Ethernet: Remote configuration and management protected by industry standard cyber security protocols. USB: Local configuration. Digital inputs: The system has two TYPE3 dual channel inputs. Alternatively, the four channels can be used as single channel digital inputs (category 2). Supporting the following functions:
    • muting signal
    • emergency stop signal
    • restart signal
    Four Output Signal Switching Devices:
    • As safety outputs: two dual-channel safety OSSDs.
    • As auxiliary outputs: four auxiliary outputs, which can be configured as signal restart feedback, fault, muting status.
    Dynamic setting of detection fields: The connection allows to have up to 32 configurations switchable in real time. SD backup, SD restore: Configurations and login credentials can be saved and restored via microSD card. Type B: C201B-C (Extended line) Part no. 90301113.210 The eXtended Line supports new advanced functions. It also supports S202A sensors and Inxpect Safety Studio application.
  • C202 offers both USB and Ethernet communication interfaces, providing local and remote configuration options. In both cases, the Inxpect Safety Application allows the configuration of sensitive levels, safety functions, size of detection fields, and the functionality of the I/O ports of the control unit.
    Secure Ethernet: Remote configuration and management protected by industry standard cyber security protocols.
    USB: Local configuration option.
    Digital inputs: The system has two TYPE3 dual channel inputs. Alternatively, the four channels can be used as single channel digital inputs (category 2). Supporting the following functions:
    • muting signal
    • emergency stop
    • restart signal
    Four Output Signal Switching Devices:
    • As safety outputs: two dual-channel safety OSSDs.
    • As auxiliary outputs: four auxiliary outputs, which can be configured as signal restart feedback, fault, muting status.
    Dynamic setting of detection fields: There are up to 8 configurations switchable in real time. Type A:
    • C202A (Core Line) Part no. 90303011
    • C202A (eXtended Line) Part no. 90303011.2B0
    The eXtended Line supports new advanced functions. It also supports S202A sensors and Inxpect Safety Studio application.
  • C202 offers both USB and Ethernet communication interfaces, providing local and remote configuration options. In both cases, the Inxpect Safety Application allows the configuration of sensitive levels, safety functions, size of detection fields, and the functionality of the I/O ports of the control unit.
    Secure Ethernet: Remote configuration and management protected by industry standard cyber security protocols.
    USB: Local configuration option.
    Digital inputs: The system has two TYPE3 dual channel inputs. Alternatively, the four channels can be used as single channel digital inputs (category 2). Supporting the following functions:
    • muting signal
    • emergency stop
    • restart signal
    Four Output Signal Switching Devices:
    • As safety outputs: two dual-channel safety OSSDs.
    • As auxiliary outputs: four auxiliary outputs, which can be configured as signal restart feedback, fault, muting status.
    Dynamic setting of detection fields: There are up to 8 configurations switchable in real time. Type B:
    • C202B (Core Line) Part no. 90303111
    • C202B (eXtended Line) Part no. 90303111.2B0
    The eXtended Line supports new advanced functions. It also supports S202A sensors and Inxpect Safety Studio application.
  • C203A provides basic but robust control functionality for any Inxpect safety radar sensor. The Inxpect Safety Application works via USB to configure the sensitivity levels, safety functions, size of detection fields, and the functionality of the I/O ports of the control unit. USB: Local configuration option. Digital inputs: The system has two TYPE3 dual channel inputs. Alternatively, the four channels can be used as single channel digital inputs (category 2). Supporting the following functions:
    • Muting signal
    • Emergency stop signal
    • Restart signal
    Four Output Signal Switching Devices:
    • As safety outputs: two dual-channel safety OSSDs.
    • As auxiliary outputs: four auxiliary outputs: four auxiliary outputs, which can be configured as signal restart feedback, fault, muting status.
    Dynamic setting of detection fields: There are up to 8 configurations switchable in real time. Type A:
    • C203A (Core Line) Part No. 90304011
    • C203A-X1 (eXtended Line) Part No. 90304011.2B0
Go to Top