Inxpect C201B-C CIP Control Unit

C201B-C provides a safety communication based on CIP Safety™ on EtherNet/IP™. The Inxpect Safety Application allows the configuration of sensitivity levels, safety functions, size of detection fields, and the functionality of the I/O ports of the control unit.

Safety fieldbus: CIP Safety™ over EtherNet/IP™.

Secure Ethernet: Remote configuration and management protected by industry standard cyber security protocols.

USB: Local configuration.

Digital inputs: The system has two TYPE3 dual channel inputs. Alternatively, the four channels can be used as single channel digital inputs (category 2). Supporting the following functions:

  • muting signal
  • emergency stop signal
  • restart signal

Four Output Signal Switching Devices:

  • As safety outputs: two dual-channel safety OSSDs.
  • As auxiliary outputs: four auxiliary outputs, which can be configured as signal restart feedback, fault, muting status.

Dynamic setting of detection fields: The connection allows to have up to 32 configurations switchable in real time.

SD backup, SD restore: Configurations and login credentials can be saved and restored via microSD card.

Type B: C201B-C (Extended line) Part no. 90301113.210

The eXtended Line supports new advanced functions. It also supports S202A sensors and Inxpect Safety Studio application.

Categories: ,

Description

  • CIP Safety™ and MODBUS
  • SD Backup/restore TYPE B
  • Outputs: 4 Outputs Signal Switching Devices (OSSDs) or 2 dual channel safety outputs
  • Safety outputs: High-side outputs (with extended protection function), Max voltage: 30 V dc | Max current: 0.4 A | Max power: 12 W
  • Inputs: 2 dual channel TYPE3 digital inputs with common GND, 4 single channel TYPE3 digital inputs with common GND [from FW 2.0.0 onwards]
  • Fieldbus interface: CIP Safety™ over EtherNet/IP™
  • MODBUS interface: Ethernet interface for real time data monitoring
  • Power supply: 24 V dc (20–28 V dc) Max current: 1 A (no OSSD)
  • Max power consumption: 5 W (no OSSD)
  • Assembly: DIN guide
  • Degree of protection: IP20
  • Terminals: Section: 1mm2 | Max Current: 4 A with 1mm2 cables
  • System configuration: Ethernet, USB

 

Go to Top