C201B-C provides a safety communication based on CIP Safety™ on EtherNet/IP™. The Inxpect Safety Application allows the configuration of sensitivity levels, safety functions, size of detection fields, and the functionality of the I/O ports of the control unit.
Safety fieldbus: CIP Safety™ over EtherNet/IP™.
Secure Ethernet: Remote configuration and management protected by industry standard cyber security protocols.
USB: Local configuration.
Digital inputs: The system has two TYPE3 dual channel inputs. Alternatively, the four channels can be used as single channel digital inputs (category 2). Supporting the following functions:
- muting signal
- emergency stop signal
- restart signal
Four Output Signal Switching Devices:
- As safety outputs: two dual-channel safety OSSDs.
- As auxiliary outputs: four auxiliary outputs, which can be configured as signal restart feedback, fault, muting status.
Dynamic setting of detection fields: The connection allows to have up to 32 configurations switchable in real time.
SD backup, SD restore: Configurations and login credentials can be saved and restored via microSD card.
Type B: C201B-C (Extended line) Part no. 90301113.210
The eXtended Line supports new advanced functions. It also supports S202A sensors and Inxpect Safety Studio application.